Document
Number |
Title |
IEC 60050-161 |
International Electrotechnical Vocabulary. Chapter 161: Electromagnetic compatibility |
IEC 60060-1 |
High-voltage test techniques. Part 1: General definitions and test requirements |
IEC 60060-2 |
High-voltage test techniques - Part 2: Measuring systems |
IEC 60060-3 |
High-voltage test techniques - Part 3: Definitions and requirements for on-site testing |
IEC 60118-13 |
Electroacoustics - Hearing aids - Part 13: Electromagnetic compatibility (EMC) |
IEC 60255-26 |
Measuring relays and protection equipment - Part 26: Electromagnetic compatibility requirements |
IEC 60469-1 |
Pulse techniques and apparatus. Part 1: Pulse terms and definitions |
IEC 60533 |
Electrical and electronic installations in ships - Electromagnetic compatibility |
IEC 60601-1-2 |
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance -
Collateral standard: Electromagnetic compatibility - Requirements and tests |
IEC 60728-2 |
Cabled distribution systems for television and sound signals - Part 2: Electromagnetic compatibility for equipment |
IEC 60728-12 |
Cabled distribution systems for television and sound signals - Part 12: Electromagnetic compatibility of systems |
|
IEC/TS 60816 |
Guide on methods of
measurement of short duration
transients on low-voltage power and
signal lines |
IEC 60870-2-1 |
Telecontrol equipment and systems - Part 2: Operating conditions - Section 1:
Power supply and electromagnetic compatibility |
IEC 60974-10 |
Arc welding equipment - Part 10: Electromagnetic compatibility (EMC) requirements |
|
IEC/TR 61000-1-1 |
Electromagnetic
compatibility (EMC) - Part 1:
General - Section 1: Application and
interpretation of fundamental
definitions and terms |
|
IEC/TS 61000-1-2 |
Electromagnetic
compatibility (EMC) - Part 1-2:
General - Methodology for the
achievement of the functional safety
of electrical and electronic
equipment with regard to
electromagnetic phenomena |
|
IEC/TR 61000-1-3 |
Electromagnetic
compatibility (EMC) - Part 1-3:
General - The effects of
high-altitude EMP (HEMP) on civil
equipment and systems |
|
IEC/TR 61000-1-4 |
Electromagnetic
compatibility (EMC) - Part 1-4:
General - Historical rationale for
the limitation of power-frequency
conducted harmonic current emissions
from equipment, in the frequency
range up to 2 kHz |
|
IEC/TR 61000-1-5 |
Electromagnetic
compatibility (EMC) - Part 1-5:
General - High power electromagnetic
(HPEM) effects on civil systems |
|
IEC/TR 61000-2-1 |
Electromagnetic
compatibility (EMC) - Part 2:
Environment - Section 1: Description
of the environment - Electromagnetic
environment for low-frequency
conducted disturbances and
signaling in public power supply
systems |
|
IEC 61000-2-2 |
Electromagnetic
compatibility (EMC) - Part 2-2:
Environment - Compatibility levels
for low-frequency conducted
disturbances and signaling in
public low-voltage power supply
systems |
|
IEC/TR 61000-2-3 |
Electromagnetic
compatibility (EMC) - Part 2:
Environment - Section 3: Description
of the environment - Radiated and
non-network-frequency-related
conducted phenomena |
|
IEC 61000-2-4 |
Electromagnetic
compatibility (EMC) - Part 2-4:
Environment - Compatibility levels
in industrial plants for
low-frequency conducted
disturbances |
|
IEC/TS 61000-2-5 |
Electromagnetic
compatibility (EMC) - Part 2:
Environment - Section 5:
Classification of electromagnetic
environments. Basic EMC
publication |
|
IEC/TR 61000-2-6 |
Electromagnetic
compatibility (EMC) - Part 2:
Environment - Section 6: Assessment
of the emission levels in the power
supply of industrial plants as
regards low-frequency conducted
disturbances |
|
IEC/TR 61000-2-7 |
Electromagnetic
compatibility (EMC) - Part 2:
Environment - Section 7: Low
frequency magnetic fields in various
environments |
|
IEC/TR 61000-2-8 |
Electromagnetic
compatibility (EMC) - Part 2-8:
Environment - Voltage dips and short
interruptions on public electric
power supply systems with
statistical measurement results |
|
IEC 61000-2-9 |
Electromagnetic
compatibility (EMC) - Part 2:
Environment - Section 9: Description
of HEMP environment - Radiated
disturbance. Basic EMC
publication |
|
IEC 61000-2-10 |
Electromagnetic
compatibility (EMC) - Part 2-10:
Environment - Description of HEMP
environment - Conducted
disturbance |
|
IEC 61000-2-11 |
Electromagnetic
compatibility (EMC) - Part 2-11:
Environment - Classification of HEMP
environments |
|
IEC 61000-2-12 |
Electromagnetic
compatibility (EMC) - Part 2-12:
Environment - Compatibility levels
for low-frequency conducted
disturbances and signaling in
public medium-voltage power supply
systems |
|
IEC 61000-2-13 |
Electromagnetic
compatibility (EMC) - Part 2-13:
Environment - High-power
electromagnetic (HPEM) environments
- Radiated and conducted |
IEC/TR 61000-2-14 |
Electromagnetic compatibility (EMC) - Part 2-14:
Environment - Overvoltages on public electricity distribution networks |
|
IEC 61000-3-2 |
Electromagnetic
compatibility (EMC) - Part 3-2:
Limits - Limits for harmonic current
emissions (equipment input current
<= 16 A per phase) |
|
IEC 61000-3-3 |
Electromagnetic
compatibility (EMC) - Part 3-3:
Limits - Limitation of voltage
changes, voltage fluctuations and
flicker in public low-voltage supply
systems, for equipment with rated
current <= 16 A per phase and not
subject to conditional
connection |
|
IEC/TS 61000-3-4 |
Electromagnetic
compatibility (EMC) - Part 3-4:
Limits - Limitation of emission of
harmonic currents in low-voltage
power supply systems for equipment
with rated current greater than 16
A |
|
IEC/TS 61000-3-5 |
Electromagnetic
compatibility (EMC) - Part 3: Limits
- Section 5: Limitation of voltage
fluctuations and flicker in
low-voltage power supply systems for
equipment with rated current greater
than 16 A |
|
IEC/TR 61000-3-6 |
Electromagnetic
compatibility (EMC) - Part 3: Limits
- Section 6: Assessment of emission
limits for distorting loads in MV
and HV power systems - Basic EMC
publication |
|
IEC/TR 61000-3-7 |
Electromagnetic
compatibility (EMC) - Part 3: Limits
- Section 7: Assessment of emission
limits for fluctuating loads in MV
and HV power systems - Basic EMC
publication |
|
IEC 61000-3-8 |
Electromagnetic
compatibility (EMC) - Part 3: Limits
- Section 8: Signaling on
low-voltage electrical installations
- Emission levels, frequency bands
and electromagnetic disturbance
levels |
|
IEC 61000-3-11 |
Electromagnetic
compatibility (EMC) - Part 3-11:
Limits - Limitation of voltage
changes, voltage fluctuations and
flicker in public low-voltage supply
systems - Equipment with rated
current <= 75 A and subject to
conditional connection |
|
IEC 61000-3-12 |
Electromagnetic
compatibility (EMC) - Part 3-12:
Limits - Limits for harmonic
currents produced by equipment
connected to public low-voltage
systems with input current >16 A
and <=75 A per phase |
IEC/TR 61000-3-13 |
Electromagnetic compatibility (EMC) - Part 3-13: Limits -
Assessment of emission limits for the connection of unbalanced installations to MV, HV and EHV power systems |
|
IEC 61000-4-1 |
Electromagnetic
compatibility (EMC) - Part 4-1:
Testing and measurement techniques -
Overview of IEC 61000-4 series |
|
IEC 61000-4-2 |
Electromagnetic
compatibility (EMC)- Part 4-2:
Testing and measurement techniques -
Electrostatic discharge immunity
test |
|
IEC 61000-4-3 |
Electromagnetic
compatibility (EMC) - Part 4-3 :
Testing and measurement techniques -
Radiated, radio-frequency,
electromagnetic field immunity
test |
|
IEC 61000-4-4 |
Electromagnetic
compatibility (EMC) - Part 4-4:
Testing and measurement techniques -
Electrical fast transient/burst
immunity test |
|
IEC 61000-4-5 |
Electromagnetic
compatibility (EMC) - Part 4-5:
Testing and measurement techniques -
Surge immunity test |
|
IEC 61000-4-6 |
Electromagnetic
compatibility (EMC) - Part 4-6:
Testing and measurement techniques -
Immunity to conducted disturbances,
induced by radio-frequency
fields |
|
IEC 61000-4-7 |
Electromagnetic
compatibility (EMC) - Part 4-7:
Testing and measurement techniques -
General guide on harmonics and
interharmonics measurements and
instrumentation, for power supply
systems and equipment connected
thereto |
|
IEC 61000-4-8 |
Electromagnetic
compatibility (EMC) - Part 4-8:
Testing and measurement techniques -
Power frequency magnetic field
immunity test |
|
IEC 61000-4-9 |
Electromagnetic
compatibility (EMC) - Part 4-9:
Testing and measurement techniques -
Pulse magnetic field immunity
test |
|
IEC 61000-4-10 |
Electromagnetic
compatibility (EMC) - Part 4-10:
Testing and measurement techniques -
Damped oscillatory magnetic field
immunity test |
|
IEC 61000-4-11 |
Electromagnetic
compatibility (EMC) - Part 4-11:
Testing and measurement techniques -
Voltage dips, short interruptions
and voltage variations immunity
tests |
|
IEC 61000-4-12 |
Electromagnetic
compatibility (EMC) - Part 4-12:
Testing and measurement techniques -
Ring wave immunity test |
|
IEC 61000-4-13 |
Electromagnetic
compatibility (EMC) - Part 4-13:
Testing and measurement techniques -
Harmonics and interharmonics
including mains signaling at a.c.
power port, low frequency immunity
tests |
|
IEC 61000-4-14 |
Electromagnetic
compatibility (EMC) - Part 4-14:
Testing and measurement techniques -
Voltage fluctuation immunity
test |
|
IEC 61000-4-15 |
Electromagnetic
compatibility (EMC) - Part 4:
Testing and measurement techniques -
Section 15: Flickermeter -
Functional and design
specifications |
|
IEC 61000-4-16 |
Electromagnetic
compatibility (EMC) - Part 4-16:
Testing and measurement techniques -
Test for immunity to conducted,
common mode disturbances in the
frequency range 0 Hz to 150 kHz |
|
IEC 61000-4-17 |
Electromagnetic
compatibility (EMC) - Part 4-17:
Testing and measurement techniques -
Ripple on d.c. input power port
immunity test |
IEC 61000-4-18 |
Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test |
|
IEC 61000-4-20 |
Electromagnetic
compatibility (EMC) - Part 4-20:
Testing and measurement techniques -
Emission and immunity testing in
transverse electromagnetic (TEM)
waveguides |
|
IEC 61000-4-21 |
Electromagnetic
compatibility (EMC) - Part 4-21:
Testing and measurement techniques -
Reverberation chamber test
methods |
|
IEC 61000-4-23 |
Electromagnetic
compatibility (EMC) - Part 4-23:
Testing and measurement techniques -
Test methods for protective devices
for HEMP and other radiated
disturbances |
|
IEC 61000-4-24 |
Electromagnetic
compatibility (EMC) - Part 4:
Testing and measurement techniques -
Section 24: Test methods for
protective devices for HEMP
conducted disturbance - Basic EMC
Publication |
|
IEC 61000-4-25 |
Electromagnetic
compatibility (EMC) - Part 4-25:
Testing and measurement techniques -
HEMP immunity test methods for
equipment and systems |
|
IEC 61000-4-27 |
Electromagnetic
compatibility (EMC) - Part 4-27:
Testing and measurement techniques -
Unbalance, immunity test |
|
IEC 61000-4-28 |
Electromagnetic
compatibility (EMC) - Part 4-28:
Testing and measurement techniques -
Variation of power frequency,
immunity test |
|
IEC 61000-4-29 |
Electromagnetic
compatibility (EMC) - Part 4-29:
Testing and measurement techniques -
Voltage dips, short interruptions
and voltage variations on d.c. input
power port immunity tests |
|
IEC 61000-4-30 |
Electromagnetic
compatibility (EMC) - Part 4-30:
Testing and measurement techniques -
Power quality measurement
methods |
|
IEC/TR 61000-4-32 |
Electromagnetic
compatibility (EMC) - Part 4-32:
Testing and measurement techniques -
High-altitude electromagnetic pulse
(HEMP) simulator compendium |
|
IEC 61000-4-33 |
Electromagnetic
compatibility (EMC) - Part 4-33:
Testing and measurement techniques -
Measurement methods for high-power
transient parameters |
|
IEC 61000-4-34 |
Electromagnetic
compatibility (EMC) - Part 4-34:
Testing and measurement techniques -
Voltage dips, short interruptions
and voltage variations immunity
tests for equipment with input
current more than 16 A per phase |
|
IEC/TR 61000-5-1 |
Electromagnetic
compatibility (EMC) - Part 5:
Installation and mitigation
guidelines - Section 1: General
considerations - Basic EMC
publication |
|
IEC/TR 61000-5-2 |
Electromagnetic
compatibility (EMC) - Part 5:
Installation and mitigation
guidelines - Section 2: Earthing and
cabling |
|
IEC/TR 61000-5-3 |
Electromagnetic
compatibility (EMC) - Part 5-3:
Installation and mitigation
guidelines - HEMP protection
concepts |
|
IEC/TS 61000-5-4 |
Electromagnetic
compatibility (EMC) - Part 5:
Installation and mitigation
guidelines - Section 4: Immunity to
HEMP - Specifications for protective
devices against HEMP radiated
disturbance. Basic EMC
Publication |
|
IEC 61000-5-5 |
Electromagnetic
compatibility (EMC) - Part 5:
Installation and mitigation
guidelines - Section 5:
Specification of protective devices
for HEMP conducted disturbance.
Basic EMC Publication |
|
IEC/TR 61000-5-6 |
Electromagnetic
compatibility (EMC) - Part 5-6:
Installation and mitigation
guidelines - Mitigation of external
EM influences |
|
IEC 61000-5-7 |
Electromagnetic
compatibility (EMC) - Part 5-7:
Installation and mitigation
guidelines - Degrees of protection
provided by enclosures against
electromagnetic disturbances (EM
code) |
|
IEC 61000-6-1 |
Electromagnetic
compatibility (EMC) - Part 6-1:
Generic standards - Immunity for
residential, commercial and
light-industrial environments |
|
IEC 61000-6-2 |
Electromagnetic
compatibility (EMC) - Part 6-2:
Generic standards - Immunity for
industrial environments |
|
IEC 61000-6-3 |
Electromagnetic
compatibility (EMC) - Part 6-3:
Generic standards - Emission
standard for residential, commercial
and light-industrial
environments |
|
IEC 61000-6-4 |
Electromagnetic
compatibility (EMC) - Part 6-4:
Generic standards - Emission
standard for industrial
environments |
|
IEC/TS 61000-6-5 |
Electromagnetic
compatibility (EMC) - Part 6-5:
Generic standards - Immunity for
power station and substation
environments |
|
IEC/TS 61000-6-6 |
Electromagnetic
compatibility (EMC) - Part 6-6:
Generic standards - HEMP immunity
for indoor equipment |
IEC 61204-3 |
Low-voltage power supplies, d.c. output - Part 3: Electromagnetic compatibility (EMC) |
IEC 61326-1 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements |
IEC 61326-2-1 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular
requirements - Test configurations, operational conditions and performance criteria for sensitive test and
measurement equipment for EMC unprotected applications |
IEC 61326-2-2 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2:
Particular requirements - Test configurations, operational conditions and performance criteria for portable test,
measuring and monitoring equipment used in low-voltage distribution systems |
IEC 61326-2-3 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3:
Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated
or remote signal conditioning |
IEC 61326-2-4 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4:
Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring
devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9 |
IEC 61326-2-5 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-5:
Particular requirements - Test configurations, operational conditions and performance criteria for field devices with
interfaces according to IEC 61784-1, CP 3/2 |
IEC 61326-2-6 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6:
Particular requirements - In vitro diagnostic (IVD) medical equipment |
IEC 61340-3-1 |
Electrostatics - Part 3-1: Methods for simulation of electrostatic effects -
Human body model (HBM) electrostatic discharge test waveforms |
IEC 61543 |
Residual current-operated protective devices (RCDs) for household and similar use - Electromagnetic compatibility |
IEC 61800-3 |
Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods |
IEC 61967-1 |
Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz -
Part 1: General conditions and definitions |
IEC 62040-2 |
Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility EMC) requirements |
IEC 62041 |
Power transformers, power supply units, reactors and similar products - EMC requirements |
IEC 62135-2 |
Resistance welding equipment - Part 2: Electromagnetic compatibility (EMC) requirements |
IEC 62153-4-0 |
Metallic communication cable test methods - Part 4-0: Electromagnetic compatibility (EMC) -
Relationship between surface transfer impedance and screening attenuation, recommended limits |
IEC 62153-4-1 |
Metallic communication cable test methods - Part 4-1: Electromagnetic compatibility (EMC) -
Introduction to electromagnetic (EMC) screening measurements |
IEC 62153-4-2 |
Metallic communication cable test methods - Part 4-2: Electromagnetic compatibility (EMC) -
Screening and coupling attenuation - Injection clamp method |
IEC 62153-4-3 |
Metallic communication cable test methods - Part 4-3: Electromagnetic compatibility (EMC) -
Surface transfer impedance - Triaxial method |
IEC 62153-4-4 |
Metallic communication cable test methods - Part 4-4: Electromagnetic compatibility (EMC) -
Shielded screening attenuation, test method for measuring of the screening attenuation as up to and above 3 GHz |
IEC 62153-4-5 |
Metallic communication cables test methods - Part 4-5: Electromagnetic compatibility (EMC) -
Coupling or screening attenuation - Absorbing clamp method |
IEC 62153-4-6 |
Metallic communication cable test methods - Part 4-6: Electromagnetic compatibility (EMC) -
Surface transfer impedance - Line injection method |
IEC 62153-4-7 |
Metallic communication cable test methods - Part 4-7: Electromagnetic compatibility (EMC) -
Test method for measuring the transfer impedance and the screening - or the coupling attenuation - Tube in tube method |
IEC 62153-4-8 |
Metallic communication cable test methods - Part 4-8: Electromagnetic compatibility (EMC) -
Capacitive coupling admittance |
IEC 62153-4-9 |
Metallic communication cable test methods - Part 4-9: Electromagnetic compatibility (EMC) -
Coupling attenuation of screened balanced cables, triaxial method |
IEC 62236-1 |
Railway applications - Electromagnetic compatibility - Part 1: General |
IEC 62236-2 |
Railway applications - Electromagnetic compatibility - Part 2: Emission of the whole railway system to the outside world |
IEC 62236-3-1 |
Railway applications - Electromagnetic compatibility - Part 3-1: Rolling stock - Train and complete vehicle |
IEC 62236-3-2 |
Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus |
IEC 62236-4 |
Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and
telecommunications apparatus |
IEC 62236-5 |
Railway applications - Electromagnetic compatibility - Part 5:
Emission and immunity of fixed power supply installations and apparatus |
IEC 62310-2 |
Static transfer systems (STS) - Part 2: Electromagnetic compatibility (EMC) requirements |
IEC/TR 62482 |
Electrical installations in ships - Electromagnetic compatibility - Optimising of cable installations on ships -
Testing method of routing distance |